Pressure Value
Use Arabic number to Figure nominal pressure, and numerical value is ten
double working pressure value regard MPa as unit, but the numerical value
of Power station valve which is used for high pressure and temperature
conditions is real working pressure value regard MPa as unit.
Power station valve Pressure value:
Nominal pressure unit : MPa
When fluid temperature =450degree C,figure the real nominal pressure.
When fluid temperature >450degree C,figure working temperature and
pressure.
Figure as follow examples:
Pw5410 : P – pressure ,
w54 – working temperature 540degree C, 10 – working pressure
10 MPa.
|
|